Step 1
Find Minimum
Exposure Needed to Print Pure
BLACK
|
|
IMPORTANT!
Before beginning the calibration
process, test the silver print development
time to assure maximum black without
lowering the high values. I use Ansel
Adams "Factorial" system described in his
book
"The
Print". I have found that since I
can control the local low value contrast
by reshaping the curve (see Step 3), I can
now develop the print longer without
blocking the low values. I am now
developing 50% longer than formerly,
achieving a richer black. Experimentation
with print development time, AND developer, needs to
be included in the calibration tests.
AND
REMEMBER, these are MY results. Yours
WILL be
different! Sometimes I think even the
phase of the moon has an effect.
|
|
Finding the exposure and development
for PERFECT BLACK
can be as simple as making a test print of
a blank strip of negative material placed
on a sheet of the photographic printing
paper to be used.
Since black is printed for areas of the
negative that have no ink, this test can
proceed before any others.
|
|
When the lighter area, exposed through the
negative material just disappears, the proper
exposure and development have been found to insure
that the areas of your image with a Photoshop value
of zero will print as the MAXIMUM
BLACK of which the paper and developer are
capable.
.In this example,
the 7th step is full black. Additional tests might
find an intermediate exposure between the 6th and
7th step which first produces black. One should
also verify that additional development will not
darken the test area.
Whereas with photographic film, the "film base
plus fog" can vary from roll to roll and film to
film, this is not the case if you use the same
material for all of your negatives. The exposure
and development values established here will remain
valid as long as the same materials are used
throughout.
The procedure above will assure PERFECT BLACK, but makes no
guarantees for the critical shades between 90% and
100% black. To assure that a Photoshop value of 5
(98% black) can be clearly distinguished from PERFECT BLACK, a test chart will
be of value. The chart shown below will be used to
establish the contrast which provides PERFECT WHITE, and will help here
to prevent excessive exposure and/or development
when searching for PERFECT
BLACK.
Create a Test
Image for use in the
calibration process.
|
The high value band (0, 2, 4,
6, 8, and 10% black), and low
value band (90, 92, 94, 96, 98,
and 100% black) should be clearly
visible in the final print, and
constitute a check on the
printable tonal RANGE of the
negative. In the center, are a
black column and a white column.
|
|
|
|
After the negative has been printed, a
strip in the middle of the white column
(dense in the negative) is covered with an
opaque tape, while a strip in the middle
of the black column (no density in the
negative) is cut away.
In the final silver contact print, the
entire "black band" should be black, and,
as we shall see in Step 2, the entire
"white band" should be white and with good
tonality in both the high and low value
scales. The final silver print should look
like the source document.
You may download the source image at
the left by performing a "Save AS" on the
image at the right, and resizeing it to
the size desired. - But be sure NOT to
resample when changing the size or you
will create fuzzy edges.
|
|
Using the chart above to find the
exposure needed for PERFECT BLACK, the fully
developed contact test strip of the test
chart above will look like this.
The exposure time at which the black
band created by the cutout area is no
longer identifiable is that which should
be used in all subsequent experiments and
production. This is the basic exposure
time for MAXIMUM BLACK
with the chosen -
- materials
- exposure light intensity and color
- developer and development time
Change any, and the value of BLACK will change!
|
|
To assure that
the light intensity with my Beseler 23CII Dual
Dichro enlarger, is the same for EACH EXPOSURE, I use an Ilford
EM10, which has the adjustment dial taped at the
setting established during the calibration process.
After allowing the enlarger light to somewhat
stabilize (a rather indeterminate time), I raise
and lower the enlarger head until both the green
and "high" red light are illuminated. This is a
very narrow range and assures maximum
repeatability. In fact, the light in my enlarger is
so unstable that the best I can get is to have both
lights flicker back and forth during the exposure.
For the materials described here, I find a 37
second exposure is very close for an EM10 setting
of 16. DO NOT assume that once set, the enlarger
illumination will remain stable. Mine changes VERY
quickly! I have chosen to -
- place the printing frame on the easel
- cover it with a black plastic sheet from a
paper package
- turn on the enlarger light source
- raise or lower the head until BOTH the high-red and green
lights on the EM 10 flicker on
- quickly turn off the enlarger light
source
- quickly remove the black sheet
- expose with the timer.
|
Home
|
Preparation
|
Step 2
|
Step 3
|
Step 4
|
Step 5
|
|
|
Image
Preparation
Material Selection
|
Find
Ink Combination
for the Proper "Effective
Density" to Print Pure
White.
|
Create
an Adjustment Curve
|
Make a
negative
|
Final
Check
|
|
|