the SEI Exposure Photometer
was manufactured by
Salford Electrical Instruments Limited, Times Mill,
Heywood, Lancashire, England. It is a unique and
marvelous instrument, which to my knowledge it is
no longer in production..
From the Introduction to the
manual:
"The S.E.I. Photometer is a precision light
measuring instrument for the photographer and
illumination engineer. For the photographer it
provides exposure values in general photography,
reversal processes, copying and enlarging and for
the accurate measurement of transmission and
reflective densities. for the illumination engineer
it is an accurate instrument for the measurement of
brightness and illumination levels.
The main feature of the S.E.I. Photometer which
makes it so suitable to solving the most difficult
problems in both these fields is its ability to
measure at a distance, over a great brightness
range, the brightness of very small areas. The
brightness range which can be measured is a million
to one and the angle subtended by the spot in the
field of view only 1/2 °.
the instrument contains its own comparison lamp
and calibration circuit which enables the user to
set this to a predetermined standard brightness
before making measurements.
For photographers the S.E.I. Photometer measures
with precision from the camera position, the
brightness of a small area of the subject and can
thus measure the brightness range of the subject.
This enables the photographer to determine with
certainty the character of his negatives."
The SEI Photometer
does contain a light sensitive photo-electric cell,
but NOT for the purpose of measuring the luminance
of the object. It is used solely to calibrate the
brightness of the small internal light bulb, which
will illuminate the "comparison spot".
To negate changes in bulb and battery condition,
a rheostat on the bottom is used to set the lamp
brightness to a specific value, measured by the
photo-electric cell, the output of which is
displayed by a microammeter on top of the unit
Once the "standard" brightness has been set for
the illuminating bulb, and thus the brightness of
the small "comparison spot", any deviation will
represent a measurable variation from the known
reference value.
The area being evaluated is viewed through a
telescopic viewfinder, in the middle of which is
the superimposed small oval "comparison spot". The
brightness of the spot is varied by rotating the
base of the instrument until it disappears (has the
same brightness as the surrounding area), at which
time the value of the spot can be read from the
scales adjacent to the rotating base.
Thus, there are 2 basic steps in the process.
- Calibrate the internal light source which
illuminates the comparison dot.
- Adjust the brightness of the dot to match
the area being evaluated.
|
|
Although, ASA, f/stop, and shutter
speed scales are present, the luminance
values are read from a scale of LOG FOOT LAMBERTS, from
which FOOT LAMBERTS,
CANDLES PER SQUARE FOOT, and EV values can be
calculated.
which yields the chart...
|
S.E.I. Exposure
Photometer
|
Pentax Digital
Spot Meter
|
|
Delicate meter
|
No moving parts -
other than
trigger and dials
|
|
1/2 degree spot
|
1 degree spot
|
|
Brightness evaluated
by visual comparison with a known
visible area.
|
Brightness measured by
light sensitive cell. Reading can
be influenced by surrounding
areas
|
Heavy
760 grams
1 lb. 11 oz.
|
Light (relatively)
270 grams
9.6 oz.
|
|
|
|
|